sebia flc assays Search Results


86
Sebia Inc involved flc iflc
Involved Flc Iflc, supplied by Sebia Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sebia+flc+assays/flc+iflc+involved/pmc12951226-91-6-11
Average 86 stars, based on 1 article reviews
involved flc iflc - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Sebia Inc antisera k&l flc
Antisera K&L Flc, supplied by Sebia Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sebia+flc+assays/antisera+k+l+flc/pmc07995444-111-12-12
Average 90 stars, based on 1 article reviews
antisera k&l flc - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sebia Inc sebia flc
Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and λ <t>FLC</t> and κ/λ ratio determined by N Latex FLC and Freelite. Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 <t>mg/l,</t> <t>Sebia</t> FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).
Sebia Flc, supplied by Sebia Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sebia+flc+assays/sebia+flc/pmc06949235-125-3-3
Average 90 stars, based on 1 article reviews
sebia flc - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sebia Inc sflc assay sebia flc
Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and λ <t>FLC</t> and κ/λ ratio determined by N Latex FLC and Freelite. Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 <t>mg/l,</t> <t>Sebia</t> FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).
Sflc Assay Sebia Flc, supplied by Sebia Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sebia+flc+assays/sflc+assay+sebia+flc/10__1515_slash_cclm___2017___5010-634-13-19
Average 90 stars, based on 1 article reviews
sflc assay sebia flc - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sebia Inc sebia flc assay
Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and λ <t>FLC</t> and κ/λ ratio determined by N Latex FLC and Freelite. Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 <t>mg/l,</t> <t>Sebia</t> FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).
Sebia Flc Assay, supplied by Sebia Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sebia+flc+assays/sebia+flc+assay/pmc06949235-100-7-7
Average 90 stars, based on 1 article reviews
sebia flc assay - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sebia Inc flc® elisa assay
Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and λ <t>FLC</t> and κ/λ ratio determined by N Latex FLC and Freelite. Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 <t>mg/l,</t> <t>Sebia</t> FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).
Flc® Elisa Assay, supplied by Sebia Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sebia+flc+assays/flc+lambda+elisa+kit/pm33593038-1322-12-11
Average 90 stars, based on 1 article reviews
flc® elisa assay - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sebia Inc flc reagent set sebia antisera k & l free light chains [pn 4836]
Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and λ <t>FLC</t> and κ/λ ratio determined by N Latex FLC and Freelite. Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 <t>mg/l,</t> <t>Sebia</t> FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).
Flc Reagent Set Sebia Antisera K & L Free Light Chains [Pn 4836], supplied by Sebia Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sebia+flc+assays/flc+reagent+set+sebia+antisera+k+++l+free+light+chains+set++pn+4836+/pmc07995444-94-7-10
Average 90 stars, based on 1 article reviews
flc reagent set sebia antisera k & l free light chains [pn 4836] - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sebia Inc n latex flc
Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and λ <t>FLC</t> and κ/λ ratio determined by N Latex FLC and Freelite. Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 <t>mg/l,</t> <t>Sebia</t> FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).
N Latex Flc, supplied by Sebia Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sebia+flc+assays/n+latex+flc/10__1515_slash_labmed___2019___0135-2738-5-9
Average 90 stars, based on 1 article reviews
n latex flc - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sebia Inc sebia flc elisa
Reference values for <t> free light chain </t> <t> (FLC) </t> quantification tests provided by the manufacturers
Sebia Flc Elisa, supplied by Sebia Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sebia+flc+assays/sebia+flc+elisa/pmc09421952-175-0-0
Average 90 stars, based on 1 article reviews
sebia flc elisa - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sebia Inc monoclonal flc
Reference values for <t> free light chain </t> <t> (FLC) </t> quantification tests provided by the manufacturers
Monoclonal Flc, supplied by Sebia Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sebia+flc+assays/monoclonal+flc/10__1515_slash_cclm___2017___5010-639-9-12
Average 90 stars, based on 1 article reviews
monoclonal flc - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sebia Inc monoclonal immunoglobulins and flc
Reference values for <t> free light chain </t> <t> (FLC) </t> quantification tests provided by the manufacturers
Monoclonal Immunoglobulins And Flc, supplied by Sebia Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sebia+flc+assays/monoclonal+immunoglobulins+and+flc/10__1159_slash_000067452-130-30-34
Average 90 stars, based on 1 article reviews
monoclonal immunoglobulins and flc - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Sebia Inc λ flc detection
Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and <t>λ</t> <t>FLC</t> and κ/λ ratio determined by N Latex FLC <t>and</t> <t>Freelite.</t> Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).
λ Flc Detection, supplied by Sebia Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sebia+flc+assays/%CE%BB+flc+detection/pmc06949235-156-13-17
Average 90 stars, based on 1 article reviews
λ flc detection - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and λ FLC and κ/λ ratio determined by N Latex FLC and Freelite. Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and λ FLC and κ/λ ratio determined by N Latex FLC and Freelite. Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).

Article Snippet: Furthermore, differences between Sebia FLC and Freelite results were also calculated for κ FLC (bias = 15.5%), λ FLC (bias = −24.4%), and κ/λ ratios (bias = 33.4%).

Techniques:

Concordance of  FLC  measurements.

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Concordance of FLC measurements.

Article Snippet: Furthermore, differences between Sebia FLC and Freelite results were also calculated for κ FLC (bias = 15.5%), λ FLC (bias = −24.4%), and κ/λ ratios (bias = 33.4%).

Techniques:

The results of κ and λ FLC and κ/λ ratio determination by Sebia FLC are compared with N Latex FLC and Freelite results using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8), or smoldering multiple myeloma (SMM, n = 6). Shown are the results of Passing–Bablok ( a ) and Bland–Altman ( b ) analyses. Bland–Altman plots indicate agreement between FLC assays. A positive bias indicates higher values for determination of FLC by Freelite or N Latex FLC compared with Sebia FLC. For a better representation of FLC results, four samples with extreme κ FLC results or κ/λ ratios were not shown (sample 1: κ FLC results of Freelite: 14,500 mg/l, N Latex FLC: 11,200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31,800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l; sample 3: κ/λ ratios of Freelite: 62,281, N Latex FLC: 727, Sebia FLC: 214; sample 4: κ/λ ratios of Freelite: 27146, N Latex FLC: 605, Sebia FLC: 406).

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: The results of κ and λ FLC and κ/λ ratio determination by Sebia FLC are compared with N Latex FLC and Freelite results using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8), or smoldering multiple myeloma (SMM, n = 6). Shown are the results of Passing–Bablok ( a ) and Bland–Altman ( b ) analyses. Bland–Altman plots indicate agreement between FLC assays. A positive bias indicates higher values for determination of FLC by Freelite or N Latex FLC compared with Sebia FLC. For a better representation of FLC results, four samples with extreme κ FLC results or κ/λ ratios were not shown (sample 1: κ FLC results of Freelite: 14,500 mg/l, N Latex FLC: 11,200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31,800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l; sample 3: κ/λ ratios of Freelite: 62,281, N Latex FLC: 727, Sebia FLC: 214; sample 4: κ/λ ratios of Freelite: 27146, N Latex FLC: 605, Sebia FLC: 406).

Article Snippet: Furthermore, differences between Sebia FLC and Freelite results were also calculated for κ FLC (bias = 15.5%), λ FLC (bias = −24.4%), and κ/λ ratios (bias = 33.4%).

Techniques:

Concordance of iFLC/niFLC.

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Concordance of iFLC/niFLC.

Article Snippet: Furthermore, differences between Sebia FLC and Freelite results were also calculated for κ FLC (bias = 15.5%), λ FLC (bias = −24.4%), and κ/λ ratios (bias = 33.4%).

Techniques: Comparison

Proposed thresholds for equivalent iFLC/niFLC ratios between different  FLC  assays.

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Proposed thresholds for equivalent iFLC/niFLC ratios between different FLC assays.

Article Snippet: Furthermore, differences between Sebia FLC and Freelite results were also calculated for κ FLC (bias = 15.5%), λ FLC (bias = −24.4%), and κ/λ ratios (bias = 33.4%).

Techniques:

Shown are λ FLC concentrations measured by Freelite, N Latex FLC, and Sebia FLC in clinical course of patients with clinically leading λ LCMM at indicated time points (tp). Patient MM47 represents a clinical course with partial response under initiated therapy resulting in a later documented progressive disease (measured by Freelite). Sebia FLC measurements, which were only accessible for time points 2–4, showed a markedly lower λ FLC. N Latex FLC results did not detect pathological λ FLC concentrations. Patient MM02 represents clinical stable disease after the first follow-up (measured by Freelite). λ FLC determination by Sebia FLC or N Latex FLC at diagnosis with response assessment with Freelite at tp1 might have lead to the wrong conclusion of progressive disease (indicated by arrow). Finding of markedly higher values can be observed also the other way around: in patient MM23, Sebia FLC detected markedly higher λ FLC values compared with Freelite and N Latex FLC.

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Shown are λ FLC concentrations measured by Freelite, N Latex FLC, and Sebia FLC in clinical course of patients with clinically leading λ LCMM at indicated time points (tp). Patient MM47 represents a clinical course with partial response under initiated therapy resulting in a later documented progressive disease (measured by Freelite). Sebia FLC measurements, which were only accessible for time points 2–4, showed a markedly lower λ FLC. N Latex FLC results did not detect pathological λ FLC concentrations. Patient MM02 represents clinical stable disease after the first follow-up (measured by Freelite). λ FLC determination by Sebia FLC or N Latex FLC at diagnosis with response assessment with Freelite at tp1 might have lead to the wrong conclusion of progressive disease (indicated by arrow). Finding of markedly higher values can be observed also the other way around: in patient MM23, Sebia FLC detected markedly higher λ FLC values compared with Freelite and N Latex FLC.

Article Snippet: Furthermore, differences between Sebia FLC and Freelite results were also calculated for κ FLC (bias = 15.5%), λ FLC (bias = −24.4%), and κ/λ ratios (bias = 33.4%).

Techniques: Biomarker Discovery

Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and λ FLC and κ/λ ratio determined by N Latex FLC and Freelite. Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and λ FLC and κ/λ ratio determined by N Latex FLC and Freelite. Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).

Article Snippet: First, the analytical performance of the novel Sebia FLC assay was investigated.

Techniques:

Concordance of  FLC  measurements.

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Concordance of FLC measurements.

Article Snippet: First, the analytical performance of the novel Sebia FLC assay was investigated.

Techniques:

The results of κ and λ FLC and κ/λ ratio determination by Sebia FLC are compared with N Latex FLC and Freelite results using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8), or smoldering multiple myeloma (SMM, n = 6). Shown are the results of Passing–Bablok ( a ) and Bland–Altman ( b ) analyses. Bland–Altman plots indicate agreement between FLC assays. A positive bias indicates higher values for determination of FLC by Freelite or N Latex FLC compared with Sebia FLC. For a better representation of FLC results, four samples with extreme κ FLC results or κ/λ ratios were not shown (sample 1: κ FLC results of Freelite: 14,500 mg/l, N Latex FLC: 11,200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31,800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l; sample 3: κ/λ ratios of Freelite: 62,281, N Latex FLC: 727, Sebia FLC: 214; sample 4: κ/λ ratios of Freelite: 27146, N Latex FLC: 605, Sebia FLC: 406).

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: The results of κ and λ FLC and κ/λ ratio determination by Sebia FLC are compared with N Latex FLC and Freelite results using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8), or smoldering multiple myeloma (SMM, n = 6). Shown are the results of Passing–Bablok ( a ) and Bland–Altman ( b ) analyses. Bland–Altman plots indicate agreement between FLC assays. A positive bias indicates higher values for determination of FLC by Freelite or N Latex FLC compared with Sebia FLC. For a better representation of FLC results, four samples with extreme κ FLC results or κ/λ ratios were not shown (sample 1: κ FLC results of Freelite: 14,500 mg/l, N Latex FLC: 11,200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31,800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l; sample 3: κ/λ ratios of Freelite: 62,281, N Latex FLC: 727, Sebia FLC: 214; sample 4: κ/λ ratios of Freelite: 27146, N Latex FLC: 605, Sebia FLC: 406).

Article Snippet: First, the analytical performance of the novel Sebia FLC assay was investigated.

Techniques:

Concordance of iFLC/niFLC.

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Concordance of iFLC/niFLC.

Article Snippet: First, the analytical performance of the novel Sebia FLC assay was investigated.

Techniques: Comparison

Proposed thresholds for equivalent iFLC/niFLC ratios between different  FLC  assays.

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Proposed thresholds for equivalent iFLC/niFLC ratios between different FLC assays.

Article Snippet: First, the analytical performance of the novel Sebia FLC assay was investigated.

Techniques:

Shown are λ FLC concentrations measured by Freelite, N Latex FLC, and Sebia FLC in clinical course of patients with clinically leading λ LCMM at indicated time points (tp). Patient MM47 represents a clinical course with partial response under initiated therapy resulting in a later documented progressive disease (measured by Freelite). Sebia FLC measurements, which were only accessible for time points 2–4, showed a markedly lower λ FLC. N Latex FLC results did not detect pathological λ FLC concentrations. Patient MM02 represents clinical stable disease after the first follow-up (measured by Freelite). λ FLC determination by Sebia FLC or N Latex FLC at diagnosis with response assessment with Freelite at tp1 might have lead to the wrong conclusion of progressive disease (indicated by arrow). Finding of markedly higher values can be observed also the other way around: in patient MM23, Sebia FLC detected markedly higher λ FLC values compared with Freelite and N Latex FLC.

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Shown are λ FLC concentrations measured by Freelite, N Latex FLC, and Sebia FLC in clinical course of patients with clinically leading λ LCMM at indicated time points (tp). Patient MM47 represents a clinical course with partial response under initiated therapy resulting in a later documented progressive disease (measured by Freelite). Sebia FLC measurements, which were only accessible for time points 2–4, showed a markedly lower λ FLC. N Latex FLC results did not detect pathological λ FLC concentrations. Patient MM02 represents clinical stable disease after the first follow-up (measured by Freelite). λ FLC determination by Sebia FLC or N Latex FLC at diagnosis with response assessment with Freelite at tp1 might have lead to the wrong conclusion of progressive disease (indicated by arrow). Finding of markedly higher values can be observed also the other way around: in patient MM23, Sebia FLC detected markedly higher λ FLC values compared with Freelite and N Latex FLC.

Article Snippet: First, the analytical performance of the novel Sebia FLC assay was investigated.

Techniques: Biomarker Discovery

Reference values for  free light chain   (FLC)  quantification tests provided by the manufacturers

Journal: EJHaem

Article Title: Evaluation of a new ELISA assay for monoclonal free‐light chain detection in patients with cardiac amyloidosis

doi: 10.1002/jha2.516

Figure Lengend Snippet: Reference values for free light chain (FLC) quantification tests provided by the manufacturers

Article Snippet: Sebia FLC ELISA can be used for the diagnosis of patients with AL amyloidosis, but its sensitivity should be improved, probably by redefining an appropriate reference range for the κ/λ ratio.

Techniques: Enzyme-linked Immunosorbent Assay

Raw free light chain (FLC) data and dFLC values of the whole cohort . ( A ) Linear regression analyses of FLC κ (left) and λ (right) values obtained by ELISA and N‐Latex presented on a Log scale. Points represent patients with AL amyloidosis (green, κ AL; light blue, λ AL), and grey triangles represent controls. Grey lines represent perfect agreement. Passing‐Bablok slope coefficient and intercept with 95% CI, Pearson r for linear fitting with 95% CI and p value, were calculated for all values and iFLC only. ( B ) Bland‐Altman plots of the agreement between N‐Latex and ELISA values for κ (left) and λ (right) FLC. The x‐axis displays the mean of Log‐transformed FLC values obtained by ELISA and N‐Latex ([LogFLC ELISA + LogFLC N‐Latex]/2); the y‐axis displays the difference (LogFLC ELISA ‐ LogFLC N‐Latex). The horizontal plain line shows the mean of the differences, and the dotted horizontal lines show the 95% CI (with back transformation of the Log values). ( C and D ) The dFLC were calculated for the 96 AL patients ( C ) and the 48 controls ( D ) using κ and λ FLC values measured with ELISA (red x) and N‐Latex (blue dots). Results were also obtained from Freelite quantification in 25 patients with AL amyloidosis (orange dots). The vertical dotted line in A separates patients with κ ( n = 18) and λ ( n = 78) AL amyloidosis. Numbers on the x‐axis corresponds to individual patients. The patients were ordered according to dFLC ELISA value (from largest to smallest). Framed numbers refer to patients’ serums displaying a peak on sEP (0.1 to 0.4 g/L, tangential skim) corresponding to the mFLC. ( E ) Receiver operating characteristic (ROC) analysis of ELISA dFLC values from the 144 patients. The area under the curve (AUC), p value, and results for a selected cut‐off point with 95% CI are reported

Journal: EJHaem

Article Title: Evaluation of a new ELISA assay for monoclonal free‐light chain detection in patients with cardiac amyloidosis

doi: 10.1002/jha2.516

Figure Lengend Snippet: Raw free light chain (FLC) data and dFLC values of the whole cohort . ( A ) Linear regression analyses of FLC κ (left) and λ (right) values obtained by ELISA and N‐Latex presented on a Log scale. Points represent patients with AL amyloidosis (green, κ AL; light blue, λ AL), and grey triangles represent controls. Grey lines represent perfect agreement. Passing‐Bablok slope coefficient and intercept with 95% CI, Pearson r for linear fitting with 95% CI and p value, were calculated for all values and iFLC only. ( B ) Bland‐Altman plots of the agreement between N‐Latex and ELISA values for κ (left) and λ (right) FLC. The x‐axis displays the mean of Log‐transformed FLC values obtained by ELISA and N‐Latex ([LogFLC ELISA + LogFLC N‐Latex]/2); the y‐axis displays the difference (LogFLC ELISA ‐ LogFLC N‐Latex). The horizontal plain line shows the mean of the differences, and the dotted horizontal lines show the 95% CI (with back transformation of the Log values). ( C and D ) The dFLC were calculated for the 96 AL patients ( C ) and the 48 controls ( D ) using κ and λ FLC values measured with ELISA (red x) and N‐Latex (blue dots). Results were also obtained from Freelite quantification in 25 patients with AL amyloidosis (orange dots). The vertical dotted line in A separates patients with κ ( n = 18) and λ ( n = 78) AL amyloidosis. Numbers on the x‐axis corresponds to individual patients. The patients were ordered according to dFLC ELISA value (from largest to smallest). Framed numbers refer to patients’ serums displaying a peak on sEP (0.1 to 0.4 g/L, tangential skim) corresponding to the mFLC. ( E ) Receiver operating characteristic (ROC) analysis of ELISA dFLC values from the 144 patients. The area under the curve (AUC), p value, and results for a selected cut‐off point with 95% CI are reported

Article Snippet: Sebia FLC ELISA can be used for the diagnosis of patients with AL amyloidosis, but its sensitivity should be improved, probably by redefining an appropriate reference range for the κ/λ ratio.

Techniques: Enzyme-linked Immunosorbent Assay, Transformation Assay

Concordance analysis and diagnostic performance . ( A ) Free light chain (FLC) concentrations measured by N‐Latex and ELISA in patients with AL amyloidosis (green, κ AL; light blue, λ AL) and in control patients (grey triangles). The grey lines delimit lower and upper reference values for FLC concentration and κ/λ ratio; points in the light grey area have normal FLC concentrations and κ/λ ratio. ( B and C ) Clinical concordance analysis of the κ/λ ratio between ELISA and N‐Latex within the AL cohort (B) and the control cohort ( C ). In B, green and blue frames delimit results for κ and λ AL amyloidosis, respectively. ( D ) Receiver operating characteristic (ROC) curve analysis of ELISA κ/λ ratio values from λ AL and control patients. The AUC, p value, and results for four selected cut‐offs points with 95% CI are reported

Journal: EJHaem

Article Title: Evaluation of a new ELISA assay for monoclonal free‐light chain detection in patients with cardiac amyloidosis

doi: 10.1002/jha2.516

Figure Lengend Snippet: Concordance analysis and diagnostic performance . ( A ) Free light chain (FLC) concentrations measured by N‐Latex and ELISA in patients with AL amyloidosis (green, κ AL; light blue, λ AL) and in control patients (grey triangles). The grey lines delimit lower and upper reference values for FLC concentration and κ/λ ratio; points in the light grey area have normal FLC concentrations and κ/λ ratio. ( B and C ) Clinical concordance analysis of the κ/λ ratio between ELISA and N‐Latex within the AL cohort (B) and the control cohort ( C ). In B, green and blue frames delimit results for κ and λ AL amyloidosis, respectively. ( D ) Receiver operating characteristic (ROC) curve analysis of ELISA κ/λ ratio values from λ AL and control patients. The AUC, p value, and results for four selected cut‐offs points with 95% CI are reported

Article Snippet: Sebia FLC ELISA can be used for the diagnosis of patients with AL amyloidosis, but its sensitivity should be improved, probably by redefining an appropriate reference range for the κ/λ ratio.

Techniques: Diagnostic Assay, Enzyme-linked Immunosorbent Assay, Control, Concentration Assay

Diagnosis performance

Journal: EJHaem

Article Title: Evaluation of a new ELISA assay for monoclonal free‐light chain detection in patients with cardiac amyloidosis

doi: 10.1002/jha2.516

Figure Lengend Snippet: Diagnosis performance

Article Snippet: Sebia FLC ELISA can be used for the diagnosis of patients with AL amyloidosis, but its sensitivity should be improved, probably by redefining an appropriate reference range for the κ/λ ratio.

Techniques: Biomarker Discovery, Enzyme-linked Immunosorbent Assay

Coherence of ELISA and N‐Latex results during monitoring of AL amyloidosis patients . The follow‐up under treatment of five AL amyloidosis patients using dFLC values calculated using N‐Latex and ELISA is shown. The first time point corresponds to diagnosis. Monoclonal components detected on sIFE are indicated for each patient. All patients, except #56, initially had a peak of entire IgG or IgA on serum electrophoresis. Triangles represent ELISA and squares, N‐Latex, with filled and open symbols referring to normal and abnormal κ/λ ratios, respectively. The black arrow indicates the time of first negative sIFE (disappearance of monoclonal component(s) detected at diagnosis). The hematologic response at the last time point is indicated (blue, N‐Latex; red, ELISA). CR, complete remission (negative sIFE and uIFE, normal FLC level and κ/λ ratio); NR, no response; VGPR, very good partial response (dFLC reduction > 50%)

Journal: EJHaem

Article Title: Evaluation of a new ELISA assay for monoclonal free‐light chain detection in patients with cardiac amyloidosis

doi: 10.1002/jha2.516

Figure Lengend Snippet: Coherence of ELISA and N‐Latex results during monitoring of AL amyloidosis patients . The follow‐up under treatment of five AL amyloidosis patients using dFLC values calculated using N‐Latex and ELISA is shown. The first time point corresponds to diagnosis. Monoclonal components detected on sIFE are indicated for each patient. All patients, except #56, initially had a peak of entire IgG or IgA on serum electrophoresis. Triangles represent ELISA and squares, N‐Latex, with filled and open symbols referring to normal and abnormal κ/λ ratios, respectively. The black arrow indicates the time of first negative sIFE (disappearance of monoclonal component(s) detected at diagnosis). The hematologic response at the last time point is indicated (blue, N‐Latex; red, ELISA). CR, complete remission (negative sIFE and uIFE, normal FLC level and κ/λ ratio); NR, no response; VGPR, very good partial response (dFLC reduction > 50%)

Article Snippet: Sebia FLC ELISA can be used for the diagnosis of patients with AL amyloidosis, but its sensitivity should be improved, probably by redefining an appropriate reference range for the κ/λ ratio.

Techniques: Enzyme-linked Immunosorbent Assay, Biomarker Discovery, Electrophoresis

Comparative analysis using Freelite, N‐Latex, and ELISA in a sub‐cohort of AL patients including difficult cases . ( A ) The dFLCs were calculated for 25 patient samples analyzed with each FLC test. Yellow circles, blue squares, and red x represent values obtained with Freelite, N‐Latex, and ELISA, respectively. A black line links results from the same patient. ( B ) FLC results, presence of an mFLC on sIFE, proteinuria, and eGFR (MDRD equation) in seven patients—all with λ AL amyloidosis—that were misdiagnosed by more than one FLC test. Green and red background indicate values below and above reference range, respectively

Journal: EJHaem

Article Title: Evaluation of a new ELISA assay for monoclonal free‐light chain detection in patients with cardiac amyloidosis

doi: 10.1002/jha2.516

Figure Lengend Snippet: Comparative analysis using Freelite, N‐Latex, and ELISA in a sub‐cohort of AL patients including difficult cases . ( A ) The dFLCs were calculated for 25 patient samples analyzed with each FLC test. Yellow circles, blue squares, and red x represent values obtained with Freelite, N‐Latex, and ELISA, respectively. A black line links results from the same patient. ( B ) FLC results, presence of an mFLC on sIFE, proteinuria, and eGFR (MDRD equation) in seven patients—all with λ AL amyloidosis—that were misdiagnosed by more than one FLC test. Green and red background indicate values below and above reference range, respectively

Article Snippet: Sebia FLC ELISA can be used for the diagnosis of patients with AL amyloidosis, but its sensitivity should be improved, probably by redefining an appropriate reference range for the κ/λ ratio.

Techniques: Enzyme-linked Immunosorbent Assay

Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and λ FLC and κ/λ ratio determined by N Latex FLC and Freelite. Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Passing–Bablok ( a ) and Bland–Altman ( b ) analyses were performed using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8) or smoldering multiple myeloma (SMM, n = 6). Shown are the results for the determination of κ and λ FLC and κ/λ ratio determined by N Latex FLC and Freelite. Bland–Altman plots reveal agreement between N Latex FLC and Freelite. A positive bias indicates higher values for the determination of FLC by Freelite compared with N Latex FLC. For a better representation of FLC results, two samples with extreme κ FLC results were not shown (sample 1: κ FLC results of Freelite: 14500 mg/l, N Latex FLC: 11200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l).

Article Snippet: Patient MM02 represents clinical stable disease after the first follow-up (measured by Freelite). λ FLC determination by Sebia FLC or N Latex FLC at diagnosis with response assessment with Freelite at tp1 might have lead to the wrong conclusion of progressive disease (indicated by arrow).

Techniques:

Concordance of FLC measurements.

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Concordance of FLC measurements.

Article Snippet: Patient MM02 represents clinical stable disease after the first follow-up (measured by Freelite). λ FLC determination by Sebia FLC or N Latex FLC at diagnosis with response assessment with Freelite at tp1 might have lead to the wrong conclusion of progressive disease (indicated by arrow).

Techniques:

The results of κ and λ FLC and κ/λ ratio determination by Sebia FLC are compared with N Latex FLC and Freelite results using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8), or smoldering multiple myeloma (SMM, n = 6). Shown are the results of Passing–Bablok ( a ) and Bland–Altman ( b ) analyses. Bland–Altman plots indicate agreement between FLC assays. A positive bias indicates higher values for determination of FLC by Freelite or N Latex FLC compared with Sebia FLC. For a better representation of FLC results, four samples with extreme κ FLC results or κ/λ ratios were not shown (sample 1: κ FLC results of Freelite: 14,500 mg/l, N Latex FLC: 11,200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31,800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l; sample 3: κ/λ ratios of Freelite: 62,281, N Latex FLC: 727, Sebia FLC: 214; sample 4: κ/λ ratios of Freelite: 27146, N Latex FLC: 605, Sebia FLC: 406).

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: The results of κ and λ FLC and κ/λ ratio determination by Sebia FLC are compared with N Latex FLC and Freelite results using 187 serum samples from patients with newly diagnosed or relapsed multiple myeloma (MM, n = 33), light-chain multiple myeloma (LCMM, n = 8), or smoldering multiple myeloma (SMM, n = 6). Shown are the results of Passing–Bablok ( a ) and Bland–Altman ( b ) analyses. Bland–Altman plots indicate agreement between FLC assays. A positive bias indicates higher values for determination of FLC by Freelite or N Latex FLC compared with Sebia FLC. For a better representation of FLC results, four samples with extreme κ FLC results or κ/λ ratios were not shown (sample 1: κ FLC results of Freelite: 14,500 mg/l, N Latex FLC: 11,200 mg/l, Sebia FLC: 3456 mg/l; sample 2: κ FLC results of Freelite: 31,800 mg/l, N Latex FLC: 5880 mg/l, Sebia FLC: 6093 mg/l; sample 3: κ/λ ratios of Freelite: 62,281, N Latex FLC: 727, Sebia FLC: 214; sample 4: κ/λ ratios of Freelite: 27146, N Latex FLC: 605, Sebia FLC: 406).

Article Snippet: Patient MM02 represents clinical stable disease after the first follow-up (measured by Freelite). λ FLC determination by Sebia FLC or N Latex FLC at diagnosis with response assessment with Freelite at tp1 might have lead to the wrong conclusion of progressive disease (indicated by arrow).

Techniques:

Shown are λ FLC concentrations measured by Freelite, N Latex FLC, and Sebia FLC in clinical course of patients with clinically leading λ LCMM at indicated time points (tp). Patient MM47 represents a clinical course with partial response under initiated therapy resulting in a later documented progressive disease (measured by Freelite). Sebia FLC measurements, which were only accessible for time points 2–4, showed a markedly lower λ FLC. N Latex FLC results did not detect pathological λ FLC concentrations. Patient MM02 represents clinical stable disease after the first follow-up (measured by Freelite). λ FLC determination by Sebia FLC or N Latex FLC at diagnosis with response assessment with Freelite at tp1 might have lead to the wrong conclusion of progressive disease (indicated by arrow). Finding of markedly higher values can be observed also the other way around: in patient MM23, Sebia FLC detected markedly higher λ FLC values compared with Freelite and N Latex FLC.

Journal: Blood Cancer Journal

Article Title: Comparison of three different serum-free light-chain assays—implications on diagnostic and therapeutic monitoring of multiple myeloma

doi: 10.1038/s41408-019-0267-8

Figure Lengend Snippet: Shown are λ FLC concentrations measured by Freelite, N Latex FLC, and Sebia FLC in clinical course of patients with clinically leading λ LCMM at indicated time points (tp). Patient MM47 represents a clinical course with partial response under initiated therapy resulting in a later documented progressive disease (measured by Freelite). Sebia FLC measurements, which were only accessible for time points 2–4, showed a markedly lower λ FLC. N Latex FLC results did not detect pathological λ FLC concentrations. Patient MM02 represents clinical stable disease after the first follow-up (measured by Freelite). λ FLC determination by Sebia FLC or N Latex FLC at diagnosis with response assessment with Freelite at tp1 might have lead to the wrong conclusion of progressive disease (indicated by arrow). Finding of markedly higher values can be observed also the other way around: in patient MM23, Sebia FLC detected markedly higher λ FLC values compared with Freelite and N Latex FLC.

Article Snippet: Patient MM02 represents clinical stable disease after the first follow-up (measured by Freelite). λ FLC determination by Sebia FLC or N Latex FLC at diagnosis with response assessment with Freelite at tp1 might have lead to the wrong conclusion of progressive disease (indicated by arrow).

Techniques: Biomarker Discovery